Step
Command
Description
3
Raisecom(config)#interface
interface-type interface-number
Enter physical layer interface
configuration mode.
4
Raisecom(config-
gigaethernet1/1/port)#no spanning-
tree bpduguard shutdown port
Manually restore interfaces that
are shut down by BPDU Guard.
When the edge interface is enabled with BPDU filtering and the device is enabled
with BPDU Guard, BPDU Guard takes effect first. Therefore, an edge interface is
shut down if it receives a BPDU.
2.6.10 Configuring MRSTP
Configure MRSTP for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#spanning-tree mrstp
pro-id
Create an MRSTP process.
3
Raisecom(config)#spanning-tree mrstp
pro-id
priority
priority
Configure the priority of a
specified process.
4
Raisecom(config)#interface
interface-type interface-number
Enter physical layer interface
configuration mode.
5
Raisecom(config-
gigaethernet1/1/port)#spanning-tree
mrstp
pro-id
Bind the interface to the
specified process.
2.6.11 Checking configurations
Use the following commands to check configuration results.
No.
Command
Description
1
Raisecom#show spanning-tree
Show basic configurations of STP.
2
Raisecom#show spanning-tree
interface-type interface-list
[ detail ]
Show STP configuration on the
interface.
3
Raisecom#show spanning-tree mrstp
pro-id
Show MRSTP configurations.