Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Use configured storage mode to deal with new generated alarm when the alarm in device
alarm table is full.
Clearing alarms
Clear the current alarm, which means deleting current alarms from the current alarm table.
The cleared alarms will be saved to the history alarm table.
Viewing alarms
The administrator can check alarms and monitor alarm directly on the ISCOM2600G-HI
series switch. If the ISCOM2600G-HI series switch is configured with NView NNM system,
the administrator can monitor alarms on the NView NNM system.
12.6.2 Preparing for configurations
Scenario
When the device fails, alarm management module will collect fault information and output
alarm occurrence time, alarm name and description information in log format to help users
locate problem quickly.
If the device is configured with the NMS, alarm can be reported directly to the NMS,
providing possible alarm causes and treatment recommendations to help users deal with fault.
If the device is configured with hardware monitoring, it will record the hardware monitoring
alarm table, generated Syslog, and sent Trap when the operation environment of the device
becomes abnormal, and notify the user of taking actions accordingly and prevent faults.
Alarm management facilitates alarm suppression, alarm auto-reporting, alarm monitoring,
alarm reverse, alarm delay, alarm memory mode, alarm clear and alarm view directly on the
device.
Prerequisite
Hardware environment monitoring alarm output:
In Syslog output mode: alarms will be generated into system logs. To send alarm to the
system log host, configure the IP address of the system log host for the device.
In Trap output mode: configure the IP address of the NMS for the device.
12.6.3 Configuring basic functions of alarm management
Configure basic information of alarm management for the ISCOM2600G-HI series switch as
below.
All following steps are optional and no sequence between them.
Enter global configuration
mode.
Raisecom(config)#alarm inhibit
enable
Enable alarm suppression.
By default, it is enabled.
Raisecom(config)#alarm auto-report
all enable
Enable alarm auto-reporting.