523
Step
Command
Description
Raisecom(config)#alarm auto-report
alarm-restype alarm-restype-value
enable
Enable alarm auto-reporting
of a specified alarm source.
Raisecom(config)#alarm auto-report
type
alarm-type
enable
Enable alarm auto-reporting
of a specified alarm type.
Raisecom(config)#alarm auto-report
type
alarm-type alarm-restype
alarm-restype-value
enable
Enable alarm auto-reporting
of a specified alarm source
and type.
4
Raisecom(config)#alarm monitor all
enable
Enable alarm monitoring.
Raisecom(config)#alarm monitor
alarm-restype alarm-restype-value
enable
Enable alarm monitoring of a
specified alarm source.
Raisecom(config)#alarm monitor type
alarm-type
enable
Enable alarm monitoring of a
specified alarm type.
Raisecom(config)#alarm monitor type
alarm-type alarm-restype alarm-
restype-value
enable
Enable alarm monitoring of a
specified alarm source and
type.
5
Raisecom(config)#alarm inverse
interface-type interface-number
{ none | auto | manual }
Configure alarm reverse
modes.
By default, it is none; in other
words, alarm reverse is
disabled.
6
Raisecom(config)#alarm { active |
cleared } delay
second
Configure alarm delay.
By default, it is 0s.
7
Raisecom(config)#alarm active
storage-mode { loop | stop}
Configure alarm storage
modes.
By default, it is stop.
8
Raisecom(config)#alarm clear all
(Optional) clear all current
alarms.
Raisecom(config)#alarm clear index
index
(Optional) clear current
alarms of the specified alarm
index.
Raisecom(config)#alarm clear
alarm-
restype alarm-restype-value
(Optional) clear current
alarms of the specified alarm
source.
Raisecom(config)#alarm clear type
alarm-type
(Optional) clear current
alarms of the specified alarm
type.
Raisecom(config)#alarm clear type
alarm-type alarm-restype alarm-
restype-value
(Optional) clear current
alarms of the specified alarm
source and type.

Table of Contents