ISCOM2600G-HI (A) Series Configuration Guide
9 OAM
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
396
Step
Command
Description
8
Raisecom(config-bfd-
session)#detect-
multiplier
multiplier
Configure the local detection multiple of the BFD
session.
By default, it is 3.
9
Raisecom(config-bfd-
session)#remote
discriminator
value
Configure the remote identifier of the BFD session.
By default, the remote identifier is displayed as 0,
which indicates that no remote identifier is
configured.
The remote identifier is automatically
generated by the system if not configured.
10
Raisecom(config-bfd-
session)#session
enable
Enable BFD session.
By default, it is disabled.
9.5.5 Checking configurations
Use the following commands to check configuration results.
No.
Command
Description
1
Raisecom#show bfd
Show BFD global configurations.
2
Raisecom#show bfd
[
session-id
] config
Show configurations of the specified BFD
session.
3
Raisecom#show bfd
[
session-id
] state
Show the status of the specified BFD session.
4
Raisecom#show bfd
[
session-id
]
statistics
Show statistics on the specified BFD session.
5
Raisecom#show bfd
[
session-id
]
diagnostic-code
Show the diagnostic code.