EasyManua.ls Logo

Raisecom ISCOM2600G-HI (A) Series - TACACS+

Raisecom ISCOM2600G-HI (A) Series
581 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
9 OAM
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
391
Step
Command
Description
6
Raisecom(config)#sla
oper-
num
availability-threshold
[ sd | ds ]
threshold
Configure the threshold in the SLA
availability test.
7
Raisecom(config)#sla
oper-
num
{ availability-trap |
availabilitychange-trap }
[ ds | sd ] enable
Enable SLA availability threshold alarm or
SLA availability threshold change alarm.
By default, they are disabled.
9.4.10 Enabling alarms
Enable alarms for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global configuration mode.
2
Raisecom(config)#sla alarm
availabilitychange enable
(Optional) enable availability
status change alarm.
3
Raisecom(config)#sla
oper-num
loss-
pkt-trap { current | average }
enable
Enable threshold crossing alarm
during operations.
Raisecom(config)#sla
oper-num
{ delay-trap | jitter-trap }
{ current | average } [ ds | sd |
two-way ] enable
4
Raisecom(config)#sla alarm threshold
enable
(Optional) enable threshold
alarm.
9.4.11 Checking configurations
Use the following commands to check configuration results.
No.
Command
Description
1
Raisecom#show sla { all |
oper-
num
} configuration
Show SLA configurations.
2
Raisecom#show sla { all |
oper-
num
} result
Show information in the current SLA
operation test period.
3
Raisecom#show sla
oper-num
threshold
Show the SLA operation threshold.
4
Raisecom#show sla
oper-num
latest statistic
Show statistics on the SLA operation
in the last complete scheduling.
5
Raisecom#show sla maintanence
Show the maintenance window status
of the device.

Table of Contents