ISCOM2600G-HI (A) Series Configuration Guide
12 System management
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
497
12.2.5 Configuring RMON historical statistics
Configure RMON historical statistics for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global
configuration mode.
2
Raisecom(config)#rmon history
interface-
type interface-list
[ shortinterval
short-period
] [ longinterval
long-
period
] [ buckets
buckets-number
]
[ owner
owner-name
]
Enable RMON
historical statistics on
an interface and
configure related
parameters.
When you use the no rmon history interface-type interface-list command to disable
RMON historical statistics on an interface, the interface will not count data and clear
all historical data collected previously.
12.2.6 Configuring RMON alarm group
Configure one RMON alarm group instance (alarm-id) to monitor one MIB variable (mibvar).
When the value of monitoring data exceeds the defined threshold, an alarm event will
generate. Record the log to send Trap to network management station according to the
definition of alarm event.
The monitored MIB variable must be real, and the data value type is correct.
If the configured variable does not exist or value type variable is incorrect, return error.
In the successfully configured alarm, if the variable cannot be collected later, close the
alarm; reconfigure the alarm if you want to monitor the variable again.
By default, the triggered event number is 0; in other words, no event will be triggered. If the
number is not zero, and there is no corresponding configuration in event group, when the
control variable is abnormal, it cannot trigger the event successfully until the event is
established.
An alarm will be triggered as long as matching the condition when the upper or lower limit
for one of the events is configured in the event table. If there is no configuration for the upper
and lower limits related alarm event (rising-event-id, falling-event-id) in the event table, no
alarm will not be generated even alarm conditions are met.
Configure the RMON alarm group for the ISCOM2600G-HI series switch as below.
Step
Command
Description
1
Raisecom#config
Enter global
configuration mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raisecom ISCOM2600G-HI (A) Series and is the answer not in the manual?

Raisecom ISCOM2600G-HI (A) Series Specifications

General IconGeneral
BrandRaisecom
ModelISCOM2600G-HI (A) Series
CategorySwitch
LanguageEnglish

Related product manuals