Raisecom
ISCOM2600G-HI (A) Series Configuration Guide
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
SwitchB(config-gigaethernet1/1/1)#port-channel 1
SwitchB(config)#interface port-channel 1
SwitchB(config-port-channel1)#mode lacp
SwitchB(config-port-channel1)#max-active links 1
SwitchB(config-gigaethernet1/1/1)#exit
SwitchB(config)#interface gigaethernet 1/1/2
SwitchB(config-gigaethernet1/1/2)#port-channel 1
SwitchB(config-gigaethernet1/1/2)#exit
Checking results
Use the show port-channel command to show global configurations of the static LACP link
aggregation on Switch A.
SwitchA#show port-channel
Group 1 information:
Mode : Lacp Load-sharing mode : src-dst-mac
MinLinks: 1 Max-links : 1
UpLinks : 2 Priority-Preemptive: Disable
Member Port : gigaethernet1/1/1 gigaethernet1/1/2
Efficient Port: gigaethernet1/1/1
Use the show lacp internal command to show configurations of local LACP interface status,
flag, interface priority, administration key, operation key, and interface state machine on
Switch A.
SwitchA#show lacp internal
Flags:
S - Device is requesting Slow LACPDUs F - Device is requesting Fast
LACPDUs
A - Device in Active mode P - Device in Passive mode MP - MLACP Peer
Port
Interface State Flag Port-Priority Admin-key Oper-
key Port-State
-------------------------------------------------------------------------
----------------------
gigaethernet1/1/1 Active SA 1000 1 1
0x3D
gigaethernet1/1/2 Standby SA 32768 1 1
0x5
Use the show lacp neighbor command to show configurations of LACP interface status, flag,
interface priority, administration key, operation key, and interface state machine of the peer
system on Switch A.
Raisecom#show lacp neighbor
Flags: