Raisecom(config-gigaethernet1/1/2)#port backup gigaethernet 1/1/1
vlanlist 151-200
Checking results
Use the show port backup group command to show status of interface backup under normal
or faulty conditions.
When both GE 1/1/1 and GE 1/1/2 are Forward, GE 1/1/1 forwards traffic of VLANs 100
150, and GE 1/1/2 forwards traffic of VLANs 151200.
Raisecom#show port backup group
Active Port(State) Backup Port(State) ForceSwitch Vlanlist
-------------------------------------------------------------------------
-------------------------------------
GE1/1/1(Forward) GE1/1/2(Block) NO 100-150
GE1/1/2(Forward) GE1/1/1(Block) NO 151-200
Manually disconnect the link between Switch A and Switch B to emulate a fault. Then, GE
1/1/1 becomes Down, and GE 1/1/2 forwards traffic of VLANs 100200.
Raisecom#show port backup group
Active Port(State) Backup Port(State) ForceSwitch Vlanlist
-------------------------------------------------------------------------
-------------------------------------
GE1/1/1(Down) GE1/1/2(Forward) NO 100-150
GE1/1/2(Forward) GE1/1/1(Down) NO 151-200
When GE 1/1/1 resumes and keeps Forward for 15s (restore-delay), it forwards traffic of
VLANs 100150 while GE 1/1/2 forwards traffic of VLANs 151200.
Raisecom#show port backup group
Active Port(State) Backup Port(State) ForceSwitch Vlanlist
-------------------------------------------------------------------------
-------------------------------------
GE1/1/1(Forward) GE1/1/2(Block) NO 100-150
GE1/1/2(Forward) GE1/1/1(Block) NO 151-200