Equipment calibration for Field-IQ 9 Field-IQ system setup
Setting Explanation
adjust this number.
4.
Place a clean empty container under the rows that contain seeds to capture the seeds
dispensed during the calibration.
WARNING Moving parts during this operation. Ensure the implement is safe to operate.
5. Tap Test.
6. The system asks if you would like to prime the system. Tap Yes. To to ensure that the seed disk
is full, the system turns the seed disks one revolution.
7. Turn on the master switch to prime the system and then when prompted on-screen, turn off
the master switch.
8. In the Number of Seed Meter Revolutions entry box, enter a value and then tap Start. The higher the
number of revolutions the more accurate the calibration. Five to 10 revolutions is
recommended.
9. Follow the on-screen prompts of operating the master switch. After the system turns the
specified number of revolutions, enter the number of seeds dispensed per row and then tap
Continue.
10. The next screen shows the minimum and maximum speeds for the target rate specified. Tap OK
and then either press Test to repeat the calibration or tap OK to continue.
11. Tap the Limits tab to show an overview of the limits that are set for Target Rate 1, Target Rate 2 and
Jump Start.
12. Tap OK.
13. Repeat steps 1 through 10 for other Rawson Control Modules that need calibration.
Hydraulics test
The purpose of the hydraulics test is to exercise the hydraulics to establish whether there is
sufficient oil flow to run the system.
1.
At the Field-IQ Calibration screen tap Hydraulic Test.
WARNING Moving parts during this operation. Make sure that the implement is safe to operate.
2. Tap Next.
3. Enter the initial motor RPM. The default setting is 300. It is recommended that you test the
motor RPM at 100 to ensure that the drive runs smoothly at slow speeds.
238 FM-1000 Integrated Display User Guide Version 9.25, Revision B