19 Diagnostics Field-IQ diagnostics
Message That Displays Explanation Possible Causes / Actions
nozzles in the Field-IQ
Setup
Controller Requires Valve
Calibration
Go to the Valve Calibration screen to
set the valve type.
Sprayer configuration error
Check the settings on the
Valve Calibration screen
The valve type, plumbing,
or auxiliary valve setting is
incorrect.
Flow meter configuration
error
Check the flow meter
calibration
The flow meter calibration
number has not been set.
Shaft encoder
configuration error
Check the Shaft Encoder
Constant in the Flow
Calibration screen
The shaft encoder constant
has not been set.
Valve configuration error
Check the valve calibration
The valve settings are not
valid for the selected valve
type.
Unknown Field-IQ
configuration error
This message shows if the
FM-1000 integrated display
does not understand the
fault code that was
received from the rate and
section control module.
Check firmware versions. Report this
fault to Trimble Support.
No flow detected The Field-IQ system
attempted to apply
material, but the flow
sensor failed to detect any
flow.
Possible causes:
l Incorrect flow calibration
l Damaged or disconnected
feedback sensor
l Broken valve wiring
Attention Minimum flow
XX gal/min is applying
The current target
application rate and speed
require a flow that is less
than the configured
minimum flow limit. The
flow will be at that limit
Version 9.25, Revision B FM-1000 Integrated Display User Guide 485