Field-IQ diagnostics 19 Diagnostics
Message That Displays Explanation Possible Causes / Actions
has been disabled.
Use switches to control
sections.
uncorrected. Due to
potential inaccuracy of the
positions, the Field-IQ
system will not switch the
boom sections
automatically. You must
control the sections
manually through the
switches.
No GPS.
Automatic rate and section
control has been disabled.
Please maintain speed at X
mph.
The Field-IQ system is no
longer adjusting the
application rate. You are
prompted to maintain the
current speed. The last
sentence appears only if
the master switch was on
at the time of the warning.
Tank/bin level is getting
low.
General system warning
Using jump start speed.
Please maintain speed at
XX mph.
The GPS speed has been
overridden with the jump
start speed. You must drive
at that speed to maintain
the current target
application rate.
A power brown-out has
occurred - check cabling
and fuses - check power
supply
Warning typically appears
when system drops under
10 V.
Check:
l Cabling and fuses
l Power supply
Section controller reported
over-current.
Section and rate control
have been disabled.
Toggle the master switch to
re-enable control.
Possible causes:
Controller is drawing too much
current.
There is an electrical short
somewhere.
Rate and Section Control
Module Not Configured
Please set the number of
Number of nozzles has not
been set.
484 FM-1000 Integrated Display User Guide Version 9.25, Revision B