19 Diagnostics Field-IQ diagnostics
Message That Displays Explanation Possible Causes / Actions
rate has been set
Please select a target rate
The calibration cannot be
completed because the
quantity dispensed is zero.
Press Edit to edit the
quantity or Restart to
restart the calibration.
The granular flow
calibration requires you to
enter the amount that was
dispensed. This message
shows if the entered
amount was zero.
Calibration Failed
The flow calibration was
cancelled
The granular calibration
failed because you
cancelled the calibration or
an error occurred.
Calibration Failed
No flow was detected
The granular flow
calibration failed because
there were no pulses
reported from the shaft
encoder.
Check that the shaft turns during
calibration.
Check the installation and wiring of
the shaft encoder.
Calibration Failed
No material was dispensed
The granular calibration
failed because you entered
zero for the actual amount
of material dispensed.
The selected target rate
and speed cannot be
achieved.
Reduce target speed or
target rate.
This shows during granular
calibration if the target rate
and target speed that you
entered require the shaft to
turn faster than the
maximum RPM that is set
in the Limits tab in the flow
calibration screen.
The selected target rate
and speed may not be
achieved.
It is recommended that the
target speed be increased.
This shows during granular
calibration if the target rate
and target speed that you
entered require the shaft to
turn slower than the
minimum RPM that is set in
the Limits tab in the flow
calibration screen.
If you choose to continue,
the Field-IQ system tries to
Version 9.25, Revision B FM-1000 Integrated Display User Guide 493