ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-23
Settings
The setting value of the second low-frequency vibration suppression. If
P1-28 is set to 0, then it will disable the second low-frequency filter.
P1-28
VSG2 Low-frequency Vibration Suppression Gain (2)
Address: 0138H
0139H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
0
Control
Mode
PT / PR
Unit
-
Range
0 ~ 9 (0: Disable the second low-frequency
filter)
Data Size
16-bit
Format
Decimal
Settings
The second low-frequency vibration suppression gain. The bigger value
it is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested to
set the value to 1.

Table of Contents

Other manuals for Delta ASDA-A2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 and is the answer not in the manual?

Delta ASDA-A2 Specifications

General IconGeneral
Control ModePosition, Speed, Torque
ModelASDA-A2 Series
Operating Voltage200 ~ 230VAC / 380 ~ 480VAC
Power Supply200-230VAC ±10%, single-phase
Communication InterfaceRS-485, CANopen
FeedbackIncremental encoder, Absolute encoder
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Operating Temperature0°C
Storage Temperature-20°C
Humidity20% to 90% RH (non-condensing)
Position Control Mode FeaturesElectronic Cam
WeightVaries depending on the model. Please refer to the specific model's datasheet.