594 Upgrade and Maintenance Manual RX2540 M2
Appendix
I Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
Pos. Label Indicator Status Description
1
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 595
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure
detected.
Possible causes:
System is out of the specified
temperature range
Defective sensor
CPU error
Error detected by server
management software
ID
ID indicator,
see also
"iRMC-
related
status
signals" on
page 595
blue on
The server has been highlighted
using ServerView Operations
Manager, iRMC web frontend or the
ID button on the front panel for easy
identification
blue
flashing
The server has been highlighted for
easy identification using the iRMC
(AVR) with disabled local VGA
output.
2
[CSS]
CSS
indicator
off
No critical event detected (CSS
component).
orange on
Prefailure event detected (CSS
component).
For HDDs see also "HDD
prefailure detection" on page 595
orange
flashing
CSS component failure detected.
!