RX2540 M2 Upgrade and Maintenance Manual 595
I For further details on detected errors, refer to the System Event Log
(SEL) or use the ServerView Operations Manager or iRMC S4 web
interface.
iRMC-related status signals
I For further information please refer to section "Updating or recovering
the iRMC" on page 104.
HDD prefailure detection
Depending on your hardware configuration HDD prefailure detection will be
supported.
The requirements are:
– iRMC Firmware 7.14 or later
– supported OOB RAID system
– RAID controllers, which are not listed in the table below
ID indicator
Global error
indicator
Description
blue flashing off
A remote connection has been
established. Local VGA output has
been disabled during the remote
session.
blue flashing orange flashing
An emergency flash of the iRMC
firmware is in progress.
RAID controllers that do not support HDD prefailure detection
D2616/MegaRAID SAS 9280-8e MegaRAID SAS9285CV-8e
D3116/D3116C D2607
Table 8: RAID controllers that do not support HDD prefailure detection