1 Web Server Function
28-4 WindO/I-NV4 User’s Manual
Web Server Function Configuration Procedure
1 On the Configuration tab, in the System Setup group, click Project.
The Project Settings dialog box is displayed.
2 Configure the items on the Web Server tab.
Use System Web Page
The Remote Control page, Remote Monitor page or System Detailed Information page of MICRO/I can be accessd
from a web browser terminal.
Use Custom Web Page
The Custom Web Page saved in the external memory device of MICRO/I can be accessd from a web browser terminal.
Refer to “1.6 Custom Web Page” on page 28-12.
Execution Interval (msec)
Specifies the interval (0 to 5000 msec) for the MICRO/I to return data.
When the remote control function and the remote monitoring function place a load on MICRO/I operation, that load
can be reduced by increasing this value.
However, the display update speed in the web browser will become slower. Change this value if the display speed of
custom web pages is slow.
Port Number
Specifies the port number to use for the web server function.
Default Showing Page
Select the web page to display first when accessing the MICRO/I from a web browser terminal.
3 Click the OK button.
(Data Type)
Remote Control and Monitoring: Select the functions that are allowed when MICRO/I is accessed from a web browser
terminal.
When the remote control or remote monitoring function is enabled, you can have the
screen automatically change to the System Information page if no operations are
performed in the Remote Control page or Remote Monitor page for the specified
time. Refer to Chapter 4 “Remote Control and Monitoring” on page 4-66.
If Device Address is selected for (Data Type), note the following points:
If the value of device address is set to 61 or higher, it will be treated as 60 minutes.
Once a network connection is established between the web browser and the MICRO/I, the timeout period
cannot be changed. The timeout period needs to be set in Device Address before a web browser access
to the MICRO/I.