134
PARAMETERS
Simple position control
474 B030
Fifth target position upper 4 digits 0 to 9999 1 0 232
475 B031
Sixth target position lower 4 digits 0 to 9999 1 0 232
476 B032
Sixth target position upper 4 digits 0 to 9999 1 0 232
477 B033
Seventh target position lower 4
digits
0 to 9999 1 0 232
478 B034
Seventh target position upper 4
digits
0 to 9999 1 0 232
479 B035
Eighth target position lower 4 digits 0 to 9999 1 0 232
480 B036
Eighth target position upper 4 digits 0 to 9999 1 0 232
481 B037
Ninth target position lower 4 digits 0 to 9999 1 0 232
482 B038
Ninth target position upper 4 digits 0 to 9999 1 0 232
483 B039
Tenth target position lower 4 digits 0 to 9999 1 0 232
484 B040
Tenth target position upper 4 digits 0 to 9999 1 0 232
485 B041
Eleventh target position lower 4
digits
0 to 9999 1 0 232
486 B042
Eleventh target position upper 4
digits
0 to 9999 1 0 232
487 B043
Twelfth target position lower 4
digits
0 to 9999 1 0 232
488 B044
Twelfth target position upper 4
digits
0 to 9999 1 0 232
489 B045
Thirteenth target position lower 4
digits
0 to 9999 1 0 232
490 B046
Thirteenth target position upper 4
digits
0 to 9999 1 0 232
491 B047
Fourteenth target position lower 4
digits
0 to 9999 1 0 232
492 B048
Fourteenth target position upper 4
digits
0 to 9999 1 0 232
493 B049
Fifteenth target position lower 4
digits
0 to 9999 1 0 232
494 B050
Fifteenth target position upper 4
digits
0 to 9999 1 0 232
Remote
output
495 M500
Remote output selection 0, 1, 10, 11 1 0 398
496 M501
Remote output data 1 0 to 4095 1 0 398
497 M502
Remote output data 2 0 to 4095 1 0 398
498 A804
PLC function flash memory clear
0, 9696
(0 to 9999)
10 545
502 N013
Stop mode selection at
communication error
0 to 3 1 0 560
Maintenance
503 E710
Maintenance timer 1 0 (1 to 9998) 1 0 282
504 E711
Maintenance timer 1 warning output
set time
0 to 9998, 9999 1 9999 282
505 M001
Speed setting reference 1 to 590 Hz 0.01 Hz 60 Hz 50 Hz 357
S-pattern
acceleration/
deceleration D
516 F400
S-pattern time at a start of
acceleration
0.1 to 2.5 s 0.1 s 0.1 s 290
517 F401
S-pattern time at a completion of
acceleration
0.1 to 2.5 s 0.1 s 0.1 s 290
518 F402
S-pattern time at a start of
deceleration
0.1 to 2.5 s 0.1 s 0.1 s 290
519 F403
S-pattern time at a completion of
deceleration
0.1 to 2.5 s 0.1 s 0.1 s 290
522 G105
Output stop frequency 0 to 590 Hz, 9999 0.01 Hz 9999 611
539 N002
Modbus-RTU communication check
time interval
0 to 999.8 s, 9999 0.1 s 9999 579
USB
547 N040
USB communication station
number
0 to 31 1 0 594
548 N041
USB communication check time
interval
0 to 999.8 s, 9999 0.1 s 9999 594
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments