(D) Operation command and frequency command
PARAMETERS
319
5
GROUP
D
: Valid : Invalid : Partially valid
Follows the Pr.338 Communication operation command source and Pr.339 Communication speed command source settings. (Refer to
page 316.)
At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.
PU stop is only enabled. PS is displayed on the operation panel during PU stop. Follows the Pr.75 Reset selection/disconnected PU
detection/PU stop selection setting. (Refer to page 259.)
Writing of some parameters may be disabled by the Pr.77 Parameter write selection setting and the operating condition. (Refer to page 267.)
Some parameters are write-enabled independently of the operation mode and command source presence/absence. Writing is also enabled
when Pr.77="2". (Refer to page 267.) Parameter clear is disabled.
When Pr.550 NET mode operation command source selection="1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection="9999" with no communication option connected.
When Pr.550 NET mode operation command source selection="0" (communication option enabled), or Pr.550 NET mode operation
command source selection="9999" with communication option connected.
Control via
USB
connector
3
(USB
connector)
9999
(automatic
recognition,
with USB
connection)
Operation
command
(start, stop)
Running
frequency
Monitor
Parameter writing
Parameter read
Inverter reset
Other than the
above
Operation
command
(start, stop)
Running
frequency
Monitor
Parameter writing
Parameter read
Inverter reset
Communicati
on option (via
communicati
on)
Operation
command
(start, stop)
Running
frequency
Monitor
Parameter writing
Parameter read
Inverter reset
External
terminal at
the control
circuit
Inverter reset
Operation
command
(start, stop)
Frequency setting
Command
source
Condition
(Pr.551
setting)
Item
Controllability in each operation mode
PU
operation
External
operation
External/
PU
combined
operation
mode 1
(Pr.79 =3)
External/
PU
combined
operation
mode 2
(Pr.79 =4)
NET
operation
(when RS-485
terminals
are
used)
NET
operation
(when
communication
option is
used)