EasyManua.ls Logo

Mitsubishi FR-A800

Mitsubishi FR-A800
746 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outline dimension drawings
SPECIFICATIONS
705
8
Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type with brake)
Dimensions table
(Unit: mm)
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2.
Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400 V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side. Refer to the FR-A800 catalog.)
Frame Number 90L
SF-V5RUF(H)
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H) , , ,
Frame Number 160M, 160L
SF-V5RUF(H) ,
SF-V5RU
F[ ]KB
SF-V5RU
F[ ]K1B
SF-V5RU
F[ ]K3B
SF-V5RU
F[ ]K4B
Flange
Number
Frame
No.
Mass
(kg)
Motor Shaft End Terminal Screw Size
D KB KD KL KP LA LB LC LE LG LL LN LZ LR Q QK S T U W
U,V,W A,B,(C) B1,B2 G1,G2
1 FF165 90L 31.5 183.6 198.5 27 220 155 165 130j6 200 3.5 12 442 4 12 50 50 40 24j6 7 4 8 M6 M4 M4 M4
2 1 FF215 100L 50 207 213 27 231 165 215 180j6 250 4 16 481.5 4 14.5 60 60 45 28j6 7 4 8 M6 M4 M4 M4
3 2 1 FF215 112M 58 228 239 27 242 178 215 180j6 250 4 16 525 4 14.5 60 60 45 28j6 7 4 8 M6 M4 M4 M4
5 3 2 FF265 132S 83 266 256 27 256 197 265 230j6 300 4 20 597 4 14.5 80 80 63 38k6 8 5 10 M6 M4 M4 M4
7 5 3 1 FF265 132M 88 266 294 27 256 197 265 230j6 300 4 20 635 4 14.5 80 80 63 38k6 8 5 10 M6 M4 M4 M4
11 7 5 2 FF300 160M 151 318 318 56 330 231 300 250j6 350 5 20 735.5 4 18.5 110 110 90 42k6 8 5 12 M8 M4 M4 M4
15 11 7 3 FF300 160L 167 318 362 56 330 231 300 250j6 350 5 20 779.5 4 18.5 110 110 90 42k6 8 5 12 M8 M4 M4 M4
1K
2K
3K
5K
7K
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Suction
Exhaust
Direction of
cooling fan wind
Terminal box for cooling fan
1
2
B
B
Section
AA
LC
LB
LG LE
LL
LR
Q
QK
D
KB
LN LZ
1
2
KD
A
A
LA
KL
φ22
KP
Section BB
U
W
T
S
Main
terminal box
Section BB
W
S
U
T
Connector (for encoder)
MS3102A20-29P
QK
Q
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Suction
Exhaust
Direction of
cooling fan wind
Terminal box for cooling fan
1
2
Section
AA
LC
LB
B
B
LR
LG LE
LL
D
KB
A
LN LZ
A
1
2
LA
KD
KL
φ22
KP
Main
terminal box
VU
B2B1
W
G1 G2
CBA
For motor (U, V, W)
For cooling fan (A, B)
For brake (B1, B2)
For thermal protector (G1, G2)
Earthing
(grounding)
terminal (M4)
Earthing
(grounding)
terminal (M4)
Main terminal box Terminal box for cooling fan
11KB
15K
Section B
B
W
S
U
T
A
A
LN LZ
2
1
LA
KD
KL
φ22
KP
Connector (for encoder)
MS3102A20-29P
QK
Q
D
Earth (ground) terminal (M8)
Mark for earthing (grounding)
Suction
Direction of
cooling fan wind
Terminal box for cooling fan
1, 2
Section
AA
LC
LB
B
B
LL
KB LR
LG
LE
Exhaust
Main
terminal box
B2B1
U
G2G1
WV
CBA
For cooling fan (A, B, C)
For motor (U, V, W)
Earthing
(grounding)
terminal (M8)
Earthing
(grounding)
terminal (M4)
For brake (B1, B2)
For thermal protector (G1, G2)
Terminal box for cooling fan
Main terminal box
indicates an inserting position of a bolt
with hex head holes for manual opening.
Make sure to earth the earth terminal of the
flange section as well as the earth terminal in
the terminal box.
0
-0.5

Table of Contents

Related product manuals