ISCOM2600G-HI (A) Series Configuration Guide
11 Reliability
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
473
Create link-state group 1. Add LAG interfaces to the link-state group.
Raisecom(config)#link-state-tracking group 1
Raisecom(config)#interface port-channel 1
Raisecom(config-port-channel1)#link-state-tracking group 1 upstream
Raisecom(config-port-channel1)#exit
Add downlink interface GE 1/1/3 to the link-state group.
Raisecom(config)#interface gigaethernet 1/1/3
Raisecom(config-gigaethernet1/1/3)#link-state-tracking group 1 downstream
Step 2 Configure link-state tracking on Switch C.
Configurations are identical to the ones on Switch A.
Checking results
Take Switch A for example.
Use the show link-state-tracking group command to show configurations of the link-state
group.
SwitchA#show link-state-tracking group 1
Link-state-tracking Group: 1
Trap State: disable
UpStream Type: port
UpStream PortList: portchannel 1
Action Mode: Shutdown-port
Action PortList: gigaethernet 1/1/3
Link-state-tracking State: normal
Fault-type: none
Use the show link-state-tracking group command to show configurations of the link-state
group after all uplinks of Switch A fails. In this case, you can learn that link-state tracking is
performed.
SwitchA#show link-state-tracking group 1
Link-state-tracking Group: 1
Trap State: enable
UpStream Type: port
UpStream PortList: portchannel 1
Action Mode: Shutdown-port
Action PortList: gigaethernet 1/1/3
Link-state-tracking State: failover
Fault-type: port-shutdown