FieldLevel II Leveling 16 Water Management setup
Blade Settings tab
Setting Explanation
Blade Step
The increment that you require the blade to move each time it
is stepped up or down by the plus or minus offset buttons.
Course Blade Step
Coarse mode enables you to offset the target height in large
increments with a single tap, such as a 0.2' fill.
The increment you want the blade to move each time it is
stepped up or down in Coarse mode.
Antenna Height Height of the antenna above the lower edge of the blade.
On-grade Limit
Distance the blade can move before the green blade height
indicators change to thin red arrows. At twice this distance, the
height indicators become thick red arrows. See Blade Settings
tab (page 304).
Disengage Raise When you disable Auto while scraping a field, you can set a
time value that will automatically raise the blade. For example,
if you set 0.5s, the blade will raise for half a second when you
turn off Auto mode.
Remote Input Auto You can attach a remote for enabling and disabling Auto
mode. This remote is controlled with the Remote Input Auto
setting.
Relative Heights tab
For survey data collection or field leveling, set relative the relative offset height so that the
coordinates are recorded relative to the offsets set for the master benchmark.
Setting Explanation
Relative Heights
Enabled: For relative heights from the master benchmark
Disabled:For GPS heights at all times
Relative X The X coordinate that will be applied to the master benchmark if relative
heights are enabled.
Relative Y The Y coordinate that will be applied to the master benchmark if relative
heights are enabled.
Height Offset The height value that will be applied to the master benchmark if relative
heights are enabled.
Force Re-Bench
If set to Yes and the field has been closed and opened again, the system
304 FM-1000 Integrated Display User Guide Version 9.25, Revision B