Field-IQ diagnostics 19 Diagnostics
Message That Displays Explanation Possible Causes / Actions
entry must differ from the
first
Please enter a different
height
process requires calibration
at two different gate
heights. This message
indicates that you entered
the same gate height twice.
Note –
Zero is a valid gate
height for calibration.
No gate height change has
been detected
Please change the gate
height
The gate height calibration
process requires calibration
at two different gate
heights. This message
indicates that the report
from the gate height sensor
did not change when the
second reading was taken.
The gate must be raised or
lowered between readings.
If this message persists after the gate
is moved, check the installation and
wiring of the gate height sensor.
Gate not open
Please open the gate
The Field-IQ system is
attempting to dispense
material, but the gate
height sensor indicates that
the gate is closed. Or if the
gate height sensor is
disabled, you did not enter
a non-zero gate height.
Open the gate, or enter a non-zero
gate height.If the gate is already
open, check the installation and
wiring of the gate height sensor.
The spinner pulses per
revolution setting is invalid
Please check the spinner
sensor setup
The tank/bin is empty
Please refill tank/bin
The tank/bin level sensor
has reported that the
tank/bin is empty.
If this is incorrect, check the tank/bin
sensor installation and wiring.
Valve Calibration Not
Started.
This shows only during
auto valve calibration,
which is not available in
firmware version 4.0. For
safety reasons, when
running an auto valve
The vehicle is moving too slow to
begin the automatic valve calibration.
Increase the speed of the vehicle and
start the valve calibration again
488 FM-1000 Integrated Display User Guide Version 9.25, Revision B