19 Diagnostics Yield Monitoring diagnostics
Warning message Explanation
manually entered moisture setting. reset.
Do you want to reset average moisture and
recalculate dry yield?
Requesting confirmation when setting manual
moisture.
Closing this field will cause your current load
being recorded to be automatically finished.
The user has chosen to close the field before
ending the load.
Would you like to clean out the moisture
sensor?
The display offers to clean out the Trimble
moisture sensor when shutting down.
Would you like to begin a new load? The Test
Weight for the new load is XXXXX.
User tapped New Load and New/End Load
Confirmation is enabled in setup.
What would you like to do? End Load, ends the
current Load. Cancel, continue with the current
Load. New Load, closes this Load and starts
another Load.
User tapped End Load and New/End Load
Confirmation is enabled in setup.
This operation will delete one or more loads
that were used in the most recent yield or
moisture calibration. These loads will not be
available for use in any future recalibration.
User is deleting a client, farm, field or event that
contains one or more loads that were used in
the current calibration.
CLAAS YIELD MONITOR: WARNING.
Uninitialized.
Error in communication with Claas yield
monitor.
CLAAS YIELD MONITOR: WARNING. Cannot
configure CAN port.
Error in communication with Claas yield
monitor.
CLAAS YIELD MONITOR: WARNING. Cannot
detect the CLAAS CAN bus.
Error in communication with Claas yield
monitor.
CLAAS YIELD MONITOR: WARNING. Cannot
configured Yield Monitoring.
Error in communication with Claas yield
monitor.
CLAAS YIELD MONITOR: WARNING. Lost CAN
communications.
Error in communication with Claas yield
monitor.
CLAAS YIELD MONITOR: WARNING. Error state. Error in communication with Claas yield
monitor.
CLAAS YIELD MONITOR: WARNING. Head
configuration differs between the FmX and
CEBIS.
The implement width in the display setup must
be set to match the width that was set in the
Claas yield monitor.
YIELD MONITOR: CAN bus error (state#XX).
Failed to detect the following device(s):-…..
John Deere moisture sensor, head unit or
armrest unit not detected. Check port
selection.
Version 9.25, Revision B FM-1000 Integrated Display User Guide 513