General notes on working with imc CANSAS modules 123
imc CANSAS Users Manual - Doc. Version 1.9 - 05.12.2014© 2014 imc Meßsysteme GmbH
There, select the identifier for the message. This identifier must be unique for each module, just like
every identifier on the CAN-Bus in general. You can also specify the maximum interval which may elapse
until the next time the imc CANSAS module receives this message. If this interval elapses and the
message doesn't arrive, all of the imc CANSAS outputs go into their rest state.
If CAN-messages setting the output values finally do arrive, the module obeys as usual.
The guarding-message's content doesn't matter. The imc CANSAS-module only responds to its presence.