158 Virtual Channels
imc CANSAS Users Manual - Doc. Version 1.9 - 05.12.2014© 2014 imc Meßsysteme GmbH
4.10.30 Greater
Parameter
Definition
1st parameter
Channel whose sample values are to be compared with the appropriate value from
the 2nd parameter
2nd parameter
Channel whose samples are to be compared with the corresponding values from
the 1st parameter or numerical value with which the sample values of the 1st
parameter are to be compared
Result channel
Digital channel; result value is respectively
TRUE (1), if 1st parameter value > 2nd parameter value
FALSE (0), if 1st parameter value 2nd parameter value
Description: The function determines whether the 1st parameter value is larger than the 2nd
parametervalue. If the 1st parameter is greater, then 1 is returned, otherwise 0 is returned.
Notes: If 2 channels are to be compared with each other, they must share the same sampling rate. If the
2nd parameteris a number, it must be specified in the same physical units as the 1st parameter.
Data types:
1st input channel
2nd parameter
Result channel
Integer or Digital
Integer or Digital
(2nd parameters input channel)
Digital
Integer or Digital
2nd parameters number
Digital
4.10.31 Greater value
Parameter
Definition
1st parameter
Channel whose sample values are to be compared with the appropriate value from
the 2nd parameter
2nd parameter
Channel whose samples are to be compared with the corresponding values from
the 1st parameter or
numerical value with which the sample values of the 1st parameter are to be
compared
Result channel
Channel containing the respective highest sample value of the two parameters
Description: The function determines which value from the two parameters is the highest.
Notes: If 2 channels are to be compared with each other, they must share the same sampling rate. If the
2nd parameter is a number, it must be specified in the same physical units as the 1st parameter.