206 Measurement Technique
imc CANSAS Users Manual - Doc. Version 1.9 - 05.12.2014© 2014 imc Meßsysteme GmbH
Message mapping dialog for a digital output bit
5.1.5.3 Calculated output signals
If the output signal is not assigned to any CAN-message (the corresponding entry in the module tree is
entitled "No CAN-bus message"), the signal value can be set according to a calculation. For this purpose,
there are functions which can also be used for virtual channels (see chapter on virtual channels ). If a
digital bit is removed from a CAN-message, then the function "Fixed digital value" is assigned by default.
A different function can be selected by the user.
Dialog for setting the defining function of an output signal not assigned to a message