SENT: Gateway from SENT to the CAN-Bus 395
imc CANSAS Users Manual - Doc. Version 1.9 - 05.12.2014© 2014 imc Meßsysteme GmbH
6.19.2.3 FAST-channel examples: Nibble order, Start bit position
The following examples conform to the nomenclature presented in Appendix A of the standard SAE J2716
of JAN2010. As an example, FAST-channels with the names Channel 1 and Channel 2 are extracted from
the SENT-message. xxx denotes data from other channels.
The examples illustrate how the parameters Nibble order, Start bit position and Number of bits are used.
Example 1 as per SAE J2716 JAN2010, A.1 Dual throttle position sensors
S&C [3] Serial Data Channel
S&C [2] Serial Data Channel
S&C [1] Reserved for specific application
S&C [0] Reserved for specific application
The example above also applies for an alternative from A.5 Pressure.