166 Virtual Channels
imc CANSAS Users Manual - Doc. Version 1.9 - 05.12.2014© 2014 imc Meßsysteme GmbH
Notes: The result clock pulse may not exceed the input channel's sampling rate.
Data types:
4.10.43 Mean value
Channel whose mean values within each reduction interval are to be
determined
Data rate of result channel
Description: The mean values within each reduction interval in the channel are determined. The
reduction interval is the clock pulse of the result channel. The values returned are a sequence of the
mean values found.
Notes: The result clock pulse may not exceed the input channel's sampling rate.
Data types:
4.10.44 Median filter
Description: Performs median filtering on the last 3 sample values. The 3 sample values are ordered by
their amplitude. The return value is the middle value in the ordered set. The result channel's first two
values are the same as those of the input channel.
Data types: