162 Virtual Channels
imc CANSAS Users Manual - Doc. Version 1.9 - 05.12.2014© 2014 imc Meßsysteme GmbH
Description: The function determines whether the 1st parameter value is less than the 2nd parameter
value. If the 1st parameter is lesser, then 1 is returned, otherwise 0 is returned.
Notes: If 2 channels are to be compared with each other, they must share the same sampling rate.
If the 2nd parameter is a number, it must be specified in the same physical units as the 1st parameter.
Data types:
Integer or Digital (2nd parameter is an input
channel)
2nd parameter is a number
4.10.36 Less value
Channel whose sample values are to be compared with the appropriate value from
the 2nd parameter
Channel whose samples are to be compared with the corresponding values from the
1st parameter or
numerical value with which the sample values of the 1st parameter are to be
compared
Channel containing the respective lowest sample value of the two parameters
Description: The function determines which value from the two parameters is the lowest.
Notes: If 2 channels are to be compared with each other, they must share the same sampling rate. If the
2nd parameter is a number, it must be specified in the same physical units as the 1st parameter.
Data types:
Integer (2nd parameter is input channel)
Digital (2nd parameter is input channel)
Integer 2nd parameter is input channel)
Digital (2nd parameter is input channel)
2nd parameter is a number