Parameter List
Parameter list (by parameter number)
PARAMETERS
125
Pr.
List
5
Motor constants
80 C101
Motor capacity
0.4 to 55 kW, 9999
0.01 kW
9999
164,
442,
452
0 to 3600 kW, 9999
0.1 kW
81 C102
Number of motor poles 2, 4, 6, 8, 10, 12, 9999 1 9999
164,
442,
452
82 C125
Motor excitation current
0 to 500 A, 9999
0.01 A
9999 442
0 to 3600 A, 9999
0.1 A
83 C104
Rated motor voltage 0 to 1000 V 0.1 V
200 V
164,
442,
452
400 V
84 C105
Rated motor frequency 10 to 400 Hz, 9999 0.01 Hz 9999
164,
442,
452
89 G932
Speed control gain (Advanced
magnetic flux vector)
0 to 200%, 9999 0.1% 9999 170
90 C120
Motor constant (R1)
0 to 50 , 9999
0.001
9999
442,
452,
536
0 to 400 m, 9999
0.01 m
91 C121
Motor constant (R2)
0 to 50 , 9999
0.001
9999 442
0 to 400 m, 9999
0.01 m
92 C122
Motor constant (L1)/d-axis
inductance (Ld)
0 to 6000mH, 9999
0.1 mH
9999
442,
452
0 to 400mH, 9999
0.01 mH
93 C123
Motor constant (L2)/q-axis
inductance (Lq)
0 to 6000mH, 9999
0.1 mH
9999
442,
452
0 to 400mH, 9999
0.01 mH
94 C124
Motor constant (X) 0 to 100%, 9999
0.1%
9999 442
0.01%
95 C111
Online auto tuning selection 0 to 2 1 0 460
96 C110
Auto tuning setting/status 0, 1, 11, 101 1 0
442,
452,
536
Adjustable 5 points V/F
100 G040
V/F1 (first frequency) 0 to 590 Hz, 9999 0.01 Hz 9999 603
101 G041
V/F1 (first frequency voltage) 0 to 1000 V 0.1 V 0 V 603
102 G042
V/F2 (second frequency) 0 to 590 Hz, 9999 0.01 Hz 9999 603
103 G043
V/F2 (second frequency voltage) 0 to 1000 V 0.1 V 0 V 603
104 G044
V/F3 (third frequency) 0 to 590 Hz, 9999 0.01 Hz 9999 603
105 G045
V/F3 (third frequency voltage) 0 to 1000 V 0.1 V 0 V 603
106 G046
V/F4 (fourth frequency) 0 to 590 Hz, 9999 0.01 Hz 9999 603
107 G047
V/F4 (fourth frequency voltage) 0 to 1000 V 0.1 V 0 V 603
108 G048
V/F5 (fifth frequency) 0 to 590 Hz, 9999 0.01 Hz 9999 603
109 G049
V/F5 (fifth frequency voltage) 0 to 1000 V 0.1 V 0 V 603
Third functions
110 F030
Third acceleration/deceleration
time
0 to 3600 s, 9999 0.1 s 9999 285
111 F031
Third deceleration time 0 to 3600 s, 9999 0.1 s 9999 285
112 G020
Third torque boost 0 to 30%, 9999 0.1% 9999 597
113 G021
Third V/F (base frequency) 0 to 590 Hz, 9999 0.01 Hz 9999 598
114 H602
Third stall prevention operation
level
0 to 400% 0.1% 150% 348
115 H603
Third stall prevention operation
frequency
0 to 590 Hz 0.01 Hz 0 Hz 348
116 M445
Third output frequency detection 0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 392
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
setting
FM CA