608 H016
Second motor permissible load
level
110 to 250%, 9999 1% 9999 331
PID
control
609 A624
PID set point/deviation input
selection
1 to 5 1 2
501,
521
610 A625
PID measured value input selection 1 to 5 1 3
501,
521
611 F003
Acceleration time at a restart 0 to 3600 s, 9999 0.1 s 9999
528,
534
Brake sequence function
639 A108
Brake opening current selection 0, 1 1 0 473
640 A109
Brake operation frequency
selection
0, 1 1 0 473
641 A130
Second brake sequence operation
selection
0, 7, 8, 9999 1 0 473
642 A120
Second brake opening frequency 0 to 30 Hz 0.01 Hz 3 Hz 473
643 A121
Second brake opening current 0 to 400% 0.1% 130% 473
644 A122
Second brake opening current
detection time
0 to 2 s 0.1 s 0.3 s 473
645 A123
Second brake operation time at
start
0 to 5 s 0.1 s 0.3 s 473
646 A124
Second brake operation frequency 0 to 30 Hz 0.01 Hz 6 Hz 473
647 A125
Second brake operation time at
stop
0 to 5 s 0.1 s 0.3 s 473
648 A126
Second deceleration detection
function selection
0, 1 1 0 473
650 A128
Second brake opening current
selection
0, 1 1 0 473
651 A129
Second brake operation frequency
selection
0, 1 1 0 473
Speed
smoothing
control
653 G410
Speed smoothing control 0 to 200% 0.1% 0% 630
654 G411
Speed smoothing cutoff frequency 0 to 120 Hz 0.01 Hz 20 Hz 630
Analog remote
output function
655 M530
Analog remote output selection 0, 1, 10, 11 1 0 400
656 M531
Analog remote output 1 800 to 1200% 0.1% 1000% 400
657 M532
Analog remote output 2 800 to 1200% 0.1% 1000% 400
658 M533
Analog remote output 3 800 to 1200% 0.1% 1000% 400
659 M534
Analog remote output 4 800 to 1200% 0.1% 1000% 400
Increased magnetic
excitation deceleration
660 G130
Increased magnetic excitation
deceleration operation selection
0, 1 1 0 624
661 G131
Magnetic excitation increase rate 0 to 40%, 9999 0.1% 9999 624
662 G132
Increased magnetic excitation
current level
0 to 300% 0.1% 100% 624
663 M060
Control circuit temperature signal
output level
0 to 100°C 1°C 0°C 404
665 G125
Regeneration avoidance frequency
gain
0 to 200% 0.1% 100% 621
668 A786
Power failure stop frequency gain 0 to 200% 0.1% 100% 540
673 G060
SF-PR slip amount adjustment
operation selection
2, 4, 6, 9999 1 9999 604
674 G061
SF-PR slip amount adjustment gain 0 to 500% 0.1% 100% 604
684 C000
Tuning data unit switchover 0, 1 1 0
442,
452
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
setting
FM CA