Parameter List
Parameter list (by parameter number)
PARAMETERS
137
Pr.
List
5
Maintenance
686 E712
Maintenance timer 2 0 (1 to 9998) 1 0 282
687 E713
Maintenance timer 2 warning output
set time
0 to 9998, 9999 1 9999 282
688 E714
Maintenance timer 3 0 (1 to 9998) 1 0 282
689 E715
Maintenance timer 3 warning output
set time
0 to 9998, 9999 1 9999 282
690 H881
Deceleration check time 0 to 3600 s, 9999 0.1 s 1 s 207
Electronic thermal
O/L relay
692 H011
Second free thermal reduction
frequency 1
0 to 590 Hz, 9999 0.01 Hz 9999 331
693 H012
Second free thermal reduction ratio
1
1 to 100% 1% 100% 331
694 H013
Second free thermal reduction
frequency 2
0 to 590 Hz, 9999 0.01 Hz 9999 331
695 H014
Second free thermal reduction ratio
2
1 to 100% 1% 100% 331
696 H015
Second free thermal reduction
frequency 3
0 to 590 Hz, 9999 0.01 Hz 9999 331
699 T740
Input terminal filter 5 to 50 ms, 9999 1 ms 9999 430
Motor constants
702 C106
Maximum motor frequency 0 to 400 Hz, 9999 0.01 Hz 9999 452
706 C130
Induced voltage constant (phi f)
0 to 5000 mV/(rad/s),
9999
0.1 mV/
(rad/s)
9999 452
707 C107
Motor inertia (integer) 10 to 999, 9999 1 9999 452
711 C131
Motor Ld decay ratio 0 to 100%, 9999 0.1% 9999 452
712 C132
Motor Lq decay ratio 0 to 100%, 9999 0.1% 9999 452
717 C182
Starting resistance tuning
compensation
0 to 200%, 9999 0.1% 9999 452
721 C185
Starting magnetic pole position
detection pulse width
0 to 6000 s, 10000 to
16000 s, 9999
1 s9999 452
724 C108
Motor inertia (exponent) 0 to 7, 9999 1 9999 452
725 C133
Motor protection current level 100 to 500%, 9999 0.1% 9999 452
738 C230
Second motor induced voltage
constant (phi f)
0 to 5000 mV/(rad/s),
9999
0.1 mV/
(rad/s)
9999 452
739 C231
Second motor Ld decay ratio 0 to 100%, 9999 0.1% 9999 452
740 C232
Second motor Lq decay ratio 0 to 100%, 9999 0.1% 9999 452
741 C282
Second starting resistance tuning
compensation
0 to 200%, 9999 0.1% 9999 452
742 C285
Second motor magnetic pole
detection pulse width
0 to 6000 s, 10000 to
16000 s, 9999
1 s9999 452
743 C206
Second motor maximum frequency 0 to 400 Hz, 9999 0.01 Hz 9999 452
744 C207
Second motor inertia (integer) 10 to 999, 9999 1 9999 452
745 C208
Second motor inertia (exponent) 0 to 7, 9999 1 9999 452
746 C233
Second motor protection current
level
100 to 500%, 9999 0.1% 9999 452
747 G350
Second motor low-speed range
torque characteristic selection
0, 9999 1 9999 176
PID control
753 A650
Second PID action selection
0, 10, 11, 20, 21, 50,
51, 60, 61, 70, 71, 80,
81, 90, 91, 100, 101,
1000, 1001, 1010,
1011, 2000, 2001,
2010, 2011
10 501
754 A652
Second PID control automatic
switchover frequency
0 to 590 Hz, 9999 0.01 Hz 9999 501
755 A651
Second PID action set point 0 to 100%, 9999 0.01% 9999 501
756 A653
Second PID proportional band 0.1 to 1000%, 9999 0.1% 100% 501
757 A654
Second PID integral time 0.1 to 3600 s, 9999 0.1 s 1 s 501
758 A655
Second PID differential time 0.01 to 10 s, 9999 0.01 s 9999 501
759 A600
PID unit selection 0 to 43, 9999 1 9999 514
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
setting
FM CA