Parameter List
Parameter list (by parameter number)
138
PARAMETERS
PID pre-charge function
760 A616
Pre-charge fault selection 0, 1 1 0 517
761 A617
Pre-charge ending level 0 to 100%, 9999 0.1% 9999 517
762 A618
Pre-charge ending time 0 to 3600 s, 9999 0.1 s 9999 517
763 A619
Pre-charge upper detection level 0 to 100%, 9999 0.1% 9999 517
764 A620
Pre-charge time limit 0 to 3600 s, 9999 0.1 s 9999 517
765 A656
Second pre-charge fault selection 0, 1 1 0 517
766 A657
Second pre-charge ending level 0 to 100%, 9999 0.1% 9999 517
767 A658
Second pre-charge ending time 0 to 3600 s, 9999 0.1 s 9999 517
768 A659
Second pre-charge upper detection
level
0 to 100%, 9999 0.1% 9999 517
769 A660
Second pre-charge time limit 0 to 3600 s, 9999 0.1 s 9999 517
Monitor
function
774 M101
Operation panel monitor selection 1
1 to 3, 5 to 14,
17 to 20, 22 to 35, 38,
40 to 45, 50 to 57, 61,
62, 64, 67, 87 to 98,
100, 9999
1 9999 359
775 M102
Operation panel monitor selection 2 1 9999 359
776 M103
Operation panel monitor selection 3 1 9999 359
777
A681
4 mA input fault operation
frequency
0 to 590 Hz, 9999 0.01 Hz 9999 426
T053
778
A682
4 mA input check filter 0 to 10 s 0.01 s 0 s 426
T054
779 N014
Operation frequency during
communication error
0 to 590 Hz, 9999 0.01 Hz 9999 560
788 G250
Low speed range torque
characteristic selection
0, 9999 1 9999 176
791 F070
Acceleration time in low-speed
range
0 to 3600 s, 9999 0.1 s 9999 285
792 F071
Deceleration time in low-speed
range
0 to 3600 s, 9999 0.1 s 9999 285
799 M520
Pulse increment setting for output
power
0.1, 1, 10, 100, 1000
kWh
0.1 kWh 1 kWh 403
800 G200
Control method selection
0 to 6, 9 to 14, 20,
100 to 106, 109 to 114
120 164
802 G102
Pre-excitation selection 0, 1 1 0 605
Torque
command
803 G210
Constant output range torque
characteristic selection
0, 1, 10, 11 1 0
185,
216
804 D400
Torque command source selection 0, 1, 3 to 6 1 0 216
805 D401
Torque command value (RAM) 600 to 1400% 1% 1000% 216
806 D402
Torque command value
(RAM,EEPROM)
600 to 1400% 1% 1000% 216
Speed limit
807 H410
Speed limit selection 0 to 2 1 0 219
808 H411
Forward rotation speed limit/speed
limit
0 to 400 Hz 0.01 Hz 60 Hz 50 Hz 219
809 H412
Reverse rotation speed limit/
reverse-side speed limit
0 to 400 Hz, 9999 0.01 Hz 9999 219
Torque limit
810 H700
Torque limit input method selection 0, 1 1 0 185
811 D030
Set resolution switchover 0, 1, 10, 11 1 0
185,
357
812 H701
Torque limit level (regeneration) 0 to 400%, 9999 0.1% 9999 185
813 H702
Torque limit level (3rd quadrant) 0 to 400%, 9999 0.1% 9999 185
814 H703
Torque limit level (4th quadrant) 0 to 400%, 9999 0.1% 9999 185
815 H710
Torque limit level 2 0 to 400%, 9999 0.1% 9999 185
816 H720
Torque limit level during
acceleration
0 to 400%, 9999 0.1% 9999 185
817 H721
Torque limit level during
deceleration
0 to 400%, 9999 0.1% 9999 185
Easy gain
tuning
818 C112
Easy gain tuning response level
setting
1 to 15 1 2 192
819 C113
Easy gain tuning selection 0 to 2 1 0 192
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
setting
FM CA

Table of Contents

Related product manuals