Parameter List
Parameter list (by parameter number)
PARAMETERS
141
Pr.
List
5
Calibration parameters
C0
(900)
M310
FM/CA terminal calibration ---375
C1
(901)
M320
AM terminal calibration ---375
C2
(902)
T200
Terminal 2 frequency setting bias
frequency
0 to 590 Hz 0.01 Hz 0 Hz 415
C3
(902)
T201
Terminal 2 frequency setting bias 0 to 300% 0.1% 0% 415
125
(903)
T202
Terminal 2 frequency setting gain
frequency
0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 415
C4
(903)
T203
Terminal 2 frequency setting gain 0 to 300% 0.1% 100% 415
C5
(904)
T400
Terminal 4 frequency setting bias
frequency
0 to 590 Hz 0.01 Hz 0 Hz 415
C6
(904)
T401
Terminal 4 frequency setting bias 0 to 300% 0.1% 20% 415
126
(905)
T402
Terminal 4 frequency setting gain
frequency
0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 415
C7
(905)
T403
Terminal 4 frequency setting gain 0 to 300% 0.1% 100% 415
C12
(917)
T100
Terminal 1 bias frequency (speed) 0 to 590 Hz 0.01 Hz 0 Hz 415
C13
(917)
T101
Terminal 1 bias (speed) 0 to 300% 0.1% 0% 415
C14
(918)
T102
Terminal 1 gain frequency (speed) 0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 415
C15
(918)
T103
Terminal 1 gain (speed) 0 to 300% 0.1% 100% 415
C16
(919)
T110
Terminal 1 bias command (torque) 0 to 400% 0.1% 0% 421
C17
(919)
T111
Terminal 1 bias (torque) 0 to 300% 0.1% 0% 421
C18
(920)
T112
Terminal 1 gain command (torque) 0 to 400% 0.1% 150% 421
C19
(920)
T113
Terminal 1 gain (torque) 0 to 300% 0.1% 100% 421
C8
(930)
M330
Current output bias signal 0 to 100% 0.1% - 0% 375
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
setting
FM CA