Parameter List
Parameter list (by parameter number)
PARAMETERS
141
Pr.
List
5
Calibration parameters
C0
(900)

M310
FM/CA terminal calibration ---375
C1
(901)

M320
AM terminal calibration ---375
C2
(902)

T200
Terminal 2 frequency setting bias
frequency
0 to 590 Hz 0.01 Hz 0 Hz 415
C3
(902)

T201
Terminal 2 frequency setting bias 0 to 300% 0.1% 0% 415
125
(903)

T202
Terminal 2 frequency setting gain
frequency
0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 415
C4
(903)

T203
Terminal 2 frequency setting gain 0 to 300% 0.1% 100% 415
C5
(904)

T400
Terminal 4 frequency setting bias
frequency
0 to 590 Hz 0.01 Hz 0 Hz 415
C6
(904)

T401
Terminal 4 frequency setting bias 0 to 300% 0.1% 20% 415
126
(905)

T402
Terminal 4 frequency setting gain
frequency
0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 415
C7
(905)

T403
Terminal 4 frequency setting gain 0 to 300% 0.1% 100% 415
C12
(917)

T100
Terminal 1 bias frequency (speed) 0 to 590 Hz 0.01 Hz 0 Hz 415
C13
(917)

T101
Terminal 1 bias (speed) 0 to 300% 0.1% 0% 415
C14
(918)

T102
Terminal 1 gain frequency (speed) 0 to 590 Hz 0.01 Hz 60 Hz 50 Hz 415
C15
(918)

T103
Terminal 1 gain (speed) 0 to 300% 0.1% 100% 415
C16
(919)

T110
Terminal 1 bias command (torque) 0 to 400% 0.1% 0% 421
C17
(919)

T111
Terminal 1 bias (torque) 0 to 300% 0.1% 0% 421
C18
(920)

T112
Terminal 1 gain command (torque) 0 to 400% 0.1% 150% 421
C19
(920)

T113
Terminal 1 gain (torque) 0 to 300% 0.1% 100% 421
C8
(930)

M330
Current output bias signal 0 to 100% 0.1% - 0% 375
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page
Customer
setting
FM CA

Table of Contents