Parameter List
Parameter list (by parameter number)
PARAMETERS
143
Pr.
List
5
1016 H021
PTC thermistor protection
detection time
0 to 60 s 1 s 0 331
Trace function
1020 A900
Trace operation selection 0 to 4 1 0 547
1021 A901
Trace mode selection 0 to 2 1 0 547
1022 A902
Sampling cycle 0 to 9 1 2 547
1023 A903
Number of analog channels 1 to 8 1 4 547
1024 A904
Sampling auto start 0, 1 1 0 547
1025 A905
Trigger mode selection 0 to 4 1 0 547
1026 A906
Number of sampling before trigger 0 to 100% 1% 90% 547
1027 A910
Analog source selection (1ch)
1 to 3, 5 to 14,
17 to 20, 22 to 24,
32 to 35, 40 to 42,
52 to 54, 61, 62, 64,
67, 70, 87 to 98,
201 to 213,
222 to 227,
230 to 232,
235 to 238
1
201 547
1028 A911
Analog source selection (2ch) 202 547
1029 A912
Analog source selection (3ch) 203 547
1030 A913
Analog source selection (4ch) 204 547
1031 A914
Analog source selection (5ch) 205 547
1032 A915
Analog source selection (6ch) 206 547
1033 A916
Analog source selection (7ch) 207 547
1034 A917
Analog source selection (8ch) 208 547
1035 A918
Analog trigger channel 1 to 8 1 1 547
1036 A919
Analog trigger operation selection 0, 1 1 0 547
1037 A920
Analog trigger level 600 to 1400 1 1000 547
1038 A930
Digital source selection (1ch)
1 to 255 1
1 547
1039 A931
Digital source selection (2ch) 2 547
1040 A932
Digital source selection (3ch) 3 547
1041 A933
Digital source selection (4ch) 4 547
1042 A934
Digital source selection (5ch) 5 547
1043 A935
Digital source selection (6ch) 6 547
1044 A936
Digital source selection (7ch) 7 547
1045 A937
Digital source selection (8ch) 8 547
1046 A938
Digital trigger channel 1 to 8 1 1 547
1047 A939
Digital trigger operation selection 0, 1 1 0 547
1048 E106
Display-off waiting time 0 to 60 min 1 min 0 262
1049 E110
USB host reset 0, 1 1 0 262
Swinging suppression control
1072 A310
DC brake judgment time for
swinging suppression control
operation
0 to 10 s 0.1 s 3 s 486
1073 A311
Swinging suppression control
operation selection
0, 1 1 0 486
1074 A312
Swinging suppression frequency 0.05 to 3 Hz, 9999 0.001 Hz 1 Hz 486
1075 A313
Swinging suppression depth 0 to 3 1 0 486
1076 A314
Swinging suppression width 0 to 3 1 0 486
1077 A315
Rope length 0.1 to 50 m 0.1 m 1 m 486
1078 A316
Trolley weight 1 to 50000 Kg 1 Kg 1 Kg 486
1079 A317
Load weight 1 to 50000 Kg 1 Kg 1 Kg 486
1103 F040
Deceleration time at emergency
stop
0 to 3600 s 0.1 s 5 s 285
Monitor
function
1106 M050
Torque monitor filter 0 to 5 s, 9999 0.01 s 9999
359
1107 M051
Running speed monitor filter 0 to 5 s, 9999 0.01 s 9999
359
1108 M052
Excitation current monitor filter 0 to 5 s, 9999 0.01 s 9999
359
1113 H414
Speed limit method selection 0 to 2, 10, 9999 1 0 219
1114 D403
Torque command reverse selection 0, 1 1 1 216
Function
Pr.
Pr.
group
Name Setting range
Minimum
setting
increments
Initial value
Refer
to
page