Status Indicator RAPs
Prelaunch Training/Review
16-311 Scanner
Scanner not detected during power up.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check connections between Scanner and IOT. Service as required (PL 18.3) (PL 18.4).
16-315 IIT Interface
IIT interface error.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Pivot down T5 T6 HVPS (REP 1.6) to access I/F PWB.
Check that connections on I/F PWB are secure.
If problem continues, replace I/F PWB (PL 9.1).