6/02
2-318
DC1632/2240
102-330, 102-331
Prelaunch Training/Review
Status Indicator RAPs
102-330 Interface with Invalid Parameter LCD
Interface failure. Incorrect parameter was detected at the Drv. I/F between the DM and LCD.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check the D-RAM and ROM.
If the problem continues, perform re-installation of the software.
102-331 UI Internal with Invalid LED Request
I/F failure in the UI. The request for lighting up an incorrect LED was received.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check the D-RAM and ROM.
If the problem continues, perform re-installation of the software.