103-338, 103-339
Prelaunch Training/Review
Status Indicator RAPs
103-338 Same Post Script Font ROMÃS Found
The system detected that the same Post Script Font ROM was installed.
Procedure
Turn the power OFF/ON. The fault is cleared.
YN
Install the appropriate Post Script Font ROM.
If the problem continues, replace the ESS PWB (PL 13.1).
Return to Service Call Procedures.
103-339 ROM DIMM Of Another Product Found
The system detected that the ROM DIMM for another machine was installed.
Procedure
Turn the power OFF/ON. The fault is cleared.
YN
Install the appropriate ROM DIMM.
If the problem continues, replace the ESS PWB (PL 13.1).
Return to Service Call Procedures.