6/02
2-269
DC1632/2240
16-705, 16-706
Status Indicator RAPs
Prelaunch Training/Review
16-705 Security Storage without HD
Registry for Secure Print has failed because Security Storage cannot be done due to no HD
available.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check whether the HD is installed.
If the problem has occurred at installation, check whether the operations for Secure Print are
correct.
16-706 Maximum User Number
The system detected that a job exceeded the maximum number of users for Secure and Proof
Prints and aborted the job. Full status was detected at HD access and a job was aborted.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Delete unwanted documents/users and retry printing.