6/02
2-23
DC1632/2240
3-333, 3-334
Status Indicator RAPs
Prelaunch Training/Review
3-333 IIT-ESS Communication Failure 14
Controller received check code error.
Procedure
Switch the power off then on. The problem is corrected.
YN
Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
check is OK, replace the IIT/IPS PWB (PL 18.3).
Return to Service Call Procedures.
3-334 IIT-ESS Communication Failure 15
Controller received check code error.
Procedure
Switch the power off then on. The problem is corrected.
YN
Reinstall the software. If the problem continues, check the IIT/IPS PWB connectors. If the
check is OK, replace the IIT/IPS PWB (PL 18.3).
Return to Service Call Procedures.