6/02
4-49
DC1632/2240
REP 6.12
Repairs and Adjustments
Prelaunch Training/Review
REP 6.12 Carriage Motor
Parts List on PL 18.5
Removal
WARNING
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1. Remove DADF (REP 5.1).
2. Remove Platen Glass (REP 6.2).
3. Remove IIT Top Cover (REP 6.3).
4. Remove Carriage Motor (Figure 1).
a. Release clamps (2).
b. Disconnect connector.
c. Remove screws (3).
d. Remove spring.
e. Remove Carriage Motor.
Figure 1 Removing Carriage Motor