6/02
3-20
DC1632/2240
IQ23
Prelaunch Training/Review
Image Quality
IQ23 BCR Checkout RAP
Procedure
The problem is very high single-color background
YN
TBD
Go to Flag 3. Check the wires associated with the problem color for an open circuit. If the wires
are OK., check the HV outputs at P 581 for open circuits or loose contacts. If the problem per-
sists, replace the Drum Cartridge for the affected color (see Machine Consumables in Section
6).
If this does not resolve the problem, replace the HVPS T7 PWB (PL 9.1).
Figure 1 IQ23 RAP Circuit Diagram
A
A