6/02
2-404
DC1632/2240
116-740, 116-741
Prelaunch Training/Review
Status Indicator RAPs
116-740 Value Calculation Error
The number calculated in the interpreter exceeded the limit value.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Remove the data that exceeds the limit value of the printer from the print data.
116-741 Form registry error
The form data cannot be registered because of the restriction of the number of forms.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Use the Operation Panel to check the registered forms, and delete unnecessary ones. Or
delete unnecessary forms.