6/02
2-319
DC1632/2240
102-332, 102-333
Status Indicator RAPs
Prelaunch Training/Review
102-332 Interface with Invalid Parameter CP
Interface failure. Incorrect parameter was detected at the Drv. I/F between the DM and CP.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check the D-RAM and ROM.
If the problem continues, perform re-installation of the software.
102-333 Interface with Impossible Communication
Interface failure. Impossible communication with the Control Panel was detected. H/W con-
nection failure in the Panel, or the internal connection was unable to be detected correctly.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the software.