6/02
2-312
DC1632/2240
102-318, 102-319
Prelaunch Training/Review
Status Indicator RAPs
102-318 Receive Finish Queue Full
The data received from the Controller exceeded the upper limit of the processing capability in
the Panel.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the software.
102-319 Send with No ACK
Serial communication failure. Sending failure, ACK was not returned.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the software.