6/02
2-323
DC1632/2240
102-340, 102-341
Status Indicator RAPs
Prelaunch Training/Review
102-340 Interface GUAM - DM I/F
Interface failure. Incorrect parameter was detected at the I/F between the GUAM and DM.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check the D-RAM and ROM. Replace the Control Panel (PL 18.2)
If the problem continues, perform re-installation of the software.
102-341 Event Queue Full
Event queue full
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Perform re-installation of the software.
If the problem continues, replace the Control Panel (PL 18.2)