6/02
2-276
DC1632/2240
16-741, 16-742
Prelaunch Training/Review
Status Indicator RAPs
16-741 Job Template Connection
Cannot connect to the Job Template Pool Server.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Connect the cable from the M/C to a network correctly.
From the destination server, check that you can identify the M/C with "ping".
Perform the "ping" test on the destination server from .
From a client PC to check that the FTP connection to the destination server is possible.
16-742 HD File
File system was full when the Job Template was stored into the local HD.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Because the scanned images may exceed HD capacity, rerun the job.
If the problem continues, Initialize the HD.
If the problem continues, replace the HD (PL 13.1).