:CALCulate:TRANsform Subsystem VNA Commands
3-68 PN: 10580-00306 Rev. E MS20xxC PM
3-11 :CALCulate:TRANsform Subsystem
Front panel soft keys that are related to distance measurements, such as the
Additional Dist Setup soft key, appear in menus only when the Setup Domain is set up for
distance.
Maximum Distance
:CALCulate:TRANsform:DISTance:MAXimum?
Description: This command returns the maximum distance in millimeters if the
current distance unit is set to meter, and otherwise returns the
maximum distance in feet. This value is set based on the number of
data points, propagation velocity, and start and stop frequency.
Syntax: :CALCulate:TRANsform:DISTance:MAXimum?
Cmd Parameter: NA (query only)
Query Response: <NR3> (millimeters or feet)
Range: –3000.0 m to +3000.0 m
Default Unit: millimeters (mm)
Front Panel
Access: Freq/Time/Dist, Additional Dist Setup, Distance Info
Distance Resolution
:CALCulate:TRANsform:DISTance:RESolution?
Description: This command returns the distance resolution in millimeters if the
current distance unit is set to meter, and otherwise returns the
resolution in feet. This value is set based on the propagation velocity,
start and stop frequency.
Syntax: :CALCulate:TRANsform:DISTance:RESolution?
Cmd Parameter: NA (query only)
Query Response: <NR3> (millimeters or feet)
Range: –3000.0 m to +3000.0 m
Default Unit: millimeters (mm)
Front Panel
Access: Freq/Time/Dist, Additional Dist Setup, Distance Info