:CALCulate:LIMit Subsystem VNA Commands
3-34 PN: 10580-00306 Rev. E MS20xxC PM
Add Limit Point
:CALCulate:LIMit:POINt:ADD
Description: Adds a new limit point to the currently active limit line. Use
:CALCulate:LIMit:TYPE to set the currently active limit line.
Syntax: :CALCulate:LIMit:POINt:ADD
Cmd Parameter: NA
Query Response: NA (no query)
Related Command: :CALCulate:LIMit:TYPE
:CALCulate:LIMit:POINt:DELete
Front Panel
Access: Shift 6 (Limit), Limit Edit, Add Point
Delete Limit Point
:CALCulate:LIMit:POINt:DELete
Description: Deletes the active trace active limit point. After deletion, the point that
is immediately to the left of the point that was deleted becomes the
active point. Note that deletion is valid only if 2 or more limit points
exist. Use :CALCulate:LIMit:TYPE to set the currently active limit
line.
Syntax: :CALCulate:LIMit:POINt:DELete
Cmd Parameter: NA
Query Response: NA (no query)
Example: To delete the currently active limit point
:CALCulate:LIMit:POINt:DELete
Related Command: :CALCulate:LIMit:POINt:ADD
Front Panel
Access: Shift 6 (Limit), Limit Edit, Delete Point