Spectrum Analyzer Commands [:SENSe] Subsystem
MS20xxC PM PN: 10580-00306 Rev. E 6-69
ACPR Channel Spacing
[:SENSe]:ACPower:BANDwidth|BWIDth:SPACing
Description: Sets the channel spacing for the ACPR measurement.
Syntax: [:SENSe]:ACPower:BANDwidth|BWIDth:SPACing <freq>
[:SENSe]:ACPower:BANDwidth|BWIDth:SPACing?
Cmd Parameter: <freq>
Query Response: <freq>
Range: 1Hz to 9GHz for MS2036C
1 Hz to 15 GHz for MS2037C
1 Hz to 20 GHz for MS2038C
Default Value: 10.35 MHz
Default Unit: Hz
Front Panel
Access: Shift-4 (Measure), ACPR, Ch Spacing
ACPR Measurement State
[:SENSe]:ACPower:STATe
Description: Sets the state of the adjacent channel power ratio measurement, ON or
OFF. When using :CONFigure:ACPower, the state is automatically
set to ON.
Syntax: [:SENSe]:ACPower:STATe OFF|ON|0|1
[:SENSe]:ACPower:STATe?
Cmd Parameter: <boolean> OFF|ON|0|1
Query Response: <bNR1> 0|1
Default Value: OFF
Front Panel
Access: NA